TAA Tools
WRKLIBAUD       WORK LIBRARY AUDITING                  TAASEHM

The Work Library  Auditing command provides  a work display  for making
changes to  the create object  auditing value for libraries.   A named,
a  generic, or all libraries  may be displayed.   Selection may be made
on the existing library create auditing value.

You must have both *AUDIT and *ALLOBJ to use WRKLIBAUD.

Note that changing  the value effects only  new objects created in  the
library.    It  does  not  change  the object  auditing  value  of  any
existing objects in the library.

A typical command would be:

            WRKLIBAUD

All  library  objects would  be displayed  with  the current  value for
create object  auditing.   Options  exist  to  display the  details  or
change  the  value.   Changes  are  made  by  using the  system  CHGLIB
command with the current value.

WRKLIBAUD escape messages you can monitor for
---------------------------------------------

None.  Escape messages from based on functions will be re-sent.

WRKLIBAUD Command parameters                          *CMD
----------------------------

   LIB           The  library to  be displayed.    *ALL is  the default
                 for all libraries.   A specific  library or a  generic
                 library may be entered.

   LIBCRTAUD     The  library create  auditing  value to  be  selected.
                 *ANY  is the  default  meaning any  value  assigned to
                 the  library.   This causes all  libraries selected by
                 the LIB parameter to be displayed.

                 *ANYRQS may  be entered to  select any libraries  with
                 *USRPRF, *CHANGE, or *ALL specified.

                 *USRPRF may  be entered  to select any  libraries with
                 *USRPRF specified.

                 *CHANGE  may be entered  to select  any libraries with
                 *CHANGE specified.

                 *ALL may  be  entered  to select  any  libraries  with
                 *ALL specified.

                 *SYSVAL may  be entered to  select any  libraries with
                 *SYSVAL specified.

                 *NONE  may  be entered  to select  any  libraries with
                 *NONE specified.


Restrictions
------------

You must have both *AUDIT and *ALLOBJ to use WRKLIBAUD.

Prerequisites
-------------

The following TAA Tools must be on your system:

     ADJVAR          Adjust variable
     CHKALLOBJ       Check *ALLOBJ special authority
     DSPOBJD2        Display Object Description 2
     RTVSPCAUT       Retrieve special authority
     SNDESCINF       Send escape information
     SNDESCMSG       Send escape message
     SNDSTSMSG       Send status message
     WRKLIBAUD       Work library auditing

Implementation
--------------

None, the tool is ready to use.

Objects used by the tool
------------------------

   Object        Type    Attribute      Src member    Src file
   ------        ----    ---------      ----------    ----------

   WRKLIBAUD     *CMD                   TAASEHM       QATTCMD
   TAASEHMC      *PGM       CLP         TAASEHMC      QATTCL
   TAASEHMC2     *PGM       CLP         TAASEHMC2     QATTCL
   TAASEHMR      *PGM       RPG         TAASEHMR      QATTRPG
   TAASEHMD      *FILE      DSPF        TAASEHMD      QATTDDS
					

Added to TAA Productivity tools March 21, 2008


Home Page Up to Top